Product Introduction: Xsn-jf-02 multi-functional partial discharge inspection instrument is a multi-functional handheld instrument, based on the ground wave, ultrasonic wave, ultra high frequency and high frequency current detection method, testing equipment partial discharge situation, can read partial discharge amplitude and spectrum waveform, can provide two-dimensional, three-dimensional spectrum storage and read functions, etc. Partial discharge of electrical equipment can be better evaluated. The multifunctional partial discharge inspection instrument is suitable for local discharge detection of GIS, switch cabinet, transformer, power cable and other electrical equipment. The equipment is portable, easy to operate, and all the tests do not have any impact on the operation of the high-pressure equipment. The product can observe the measured signal in multiple periods, identify the frequency of discharge, and analyze it through a variety of modes, so as to clearly judge the fault.
Product name: partial discharge detector, ultrasonic partial discharge detector, partial discharge tester, local discharge detector, local discharge detector.
Test subjects:
The ultrasonic signal is received to judge the existence and position of partial discharge.
Host parameters:
1. Number of detectable channels: 4 channels, 1 TEV, 1 US, 1 UHF, 1 HFCT
2. Sampling accuracy: 12bit
3, synchronization mode: internal synchronization, external synchronization, optical synchronization
TEV parameters:
1. Detection bandwidth: 3m-80mhz
2, measuring range: 0~60dB
3, the measurement error: ±1dB
4, resolution: 1dB
5. Maximum number of pulses per cycle: 720
6. Minimum pulse frequency: 10Hz
7, output interface: standard SMA connection host
Non-contact US parameters:
1. Center frequency: 40kHz
2, resolution: 0.1UV
3, accuracy: ±0.1uV true
4, measuring range: 0.5UV ~ 1mV
5, output interface: standard SMA connection host
Contact US parameters:
1, frequency range: 20khz-300khz
2, output impedance: 50 ω
3. Detection sensitivity: 0.1mV
4, measuring range: 0.1mV ~ 1V
5, output interface: standard SMA connection host
UHF parameters:
1. Detection bandwidth: 300MhZ-1.5ghz
2, output mode: BNC interface - signal conditioning unit, wireless WiFi connection to the host
3. Receiving mode: antenna receiving
4. Transmission mode: coaxial cable
5, detection sensitivity: < -60dbm
HFCT parameters:
1. Detection bandwidth: 100K-50mhz
2, transmission impedance: >5mV/mA(10MHz)
3, output impedance: 50 ω
4. Detection sensitivity: 5pC
5, measuring range: -20~80dB
6, the measurement error: ±1dB
7, resolution: 1dB
8, output interface: BNC interface - signal conditioning unit, wireless WiFi connection to the host
Hardware parameters:
1, display: 4.3 "TFT true color LCD screen
2, resolution: 480×272
3, operation: film button
4, storage: SD card standard 4G card, the maximum support 32G
5,Interface: 3.5mm stereo headphone jack
Input port for DC-005 low voltage DC charger
Charging LED indicator light
RS232 debug port
Profile synchronous mouth
USB2.0
internet access
SD card slot
6, the power supply
Internal power supply: Battery powered (16.8V lithium battery)
Normal working time: about 7 hours, full time about 3 hours
7, size: 235mm×133mm×48mm
8, weight: 0.85kg
9, the use of ambient temperature: -20℃ to 50℃
10, storage environment temperature: -40℃ ~ 70℃
11, humidity: 10%-90% (non-condensing)