Product introduction:
XSN-ACC04 battery charge-discharge tester uses PTC ceramic resistance as discharge load, TGBT control technology to achieve the automatic adjustment and monitoring of current, perfect protection function and the application of new materials completely avoid the phenomenon of red heat. The whole discharge process is safer.
Product features:
1, adopt PTC ceramic resistance, avoid red heat phenomenon, make the whole discharge process more safe;
2, with large LCD screen, 5.0 inch touch screen, full Chinese graphical interface, easy to operate, easy to use;
3, with wireless communication function, wireless collection box and discharge host through wireless communication, simplify wiring, flexible and convenient;
4, wireless acquisition box can monitor each battery, to achieve a complete monitoring of the battery discharge process;
5, adopt intelligent MCU ARM control, LCD Display in Chinese and English. Simple menu operation;
6. Test/discharge termination conditions can be set, including single battery voltage, battery pack termination voltage, discharge current and discharge time;
7, it can record the test/discharge process, mainly including the total capacity, total voltage, total current of the battery pack and the voltage change of the single battery with the lowest voltage;
8, real-time online display, detection, recording the battery parameters, automatic storage data after the completion of the test;
9, large LCD display, Chinese menu prompt, easy to operate, high degree of intelligence;
10, can set and control the voltage, current, time, capacity and other parameters, automatically complete the battery test parameters;
11, automatic discharge, prolong the life of the battery;
12, after the discharge, the test data can be transferred to the U disk on site; The supporting data processing software processes the data collected by the discharge, analyzes the battery capacity, and generates various charts.
Technical parameters:
1, working power supply: AC220V
2. Battery voltage: DC380V
3, discharge current: 0 ~ 30A
4, discharge termination voltage: 300-456V
5, discharge current accuracy: 1%
6, current resolution: 0.1a or 1%
7, voltage test accuracy: 0.5%
8, communication interface: USB, RS232
9. Sampling interval: 10s
10, working humidity: 5% ~ 90%
11, working temperature: 0℃ ~ 50℃
12, heat dissipation mode: forced air cooling
13, all kinds of special specifications of the meter can be customized according to customer requirements